| PV String Input Data |
| Max. PV Input Power (W) |
210-460 (4 Pieces) |
210-560 (4 Pieces) |
210-630 (4 Pieces) |
210-700 (4 Pieces) |
210-770 (4 Pieces) |
| Max. PV Input Voltage (V) |
60 |
| Start-up Voltage (V) |
20 |
| MPPT Voltage Range (V) |
25-55 |
| Rated PV Input Voltage (V) |
42.5 |
| Max. Operating PV Input Current (A) |
15+15+15+15 |
18+18+18+18 |
| Max. Input Short Circuit Current (A) |
22.5+22.5+22.5+22.5 |
27+27+27+27 |
| AC Output Side |
| Rated AC Output Active Power (W) |
1300 |
1600 |
1800 |
2000 |
2200 |
| Rated AC Output Apparent Power (VA) |
1300 |
1600 |
1800 |
2000 |
2200 |
| Max. AC Output Current (A) |
6/5.7 |
7.3/7 |
8.2/7.9 |
9.1/8.7 |
10/9.6 |
| Rated Output Current (A) |
6/5.7 |
7.3/7 |
8.2/7.9 |
9.1/8.7 |
10/9.6 |
| Rated Output Voltage/Range (V) |
220/230 0.85Un-1.1Un |
| Grid Connection Form |
L/N/PE |
| Rated Output Grid Frequency/Range(Hz) |
50/45-55,60/55-65 |
| Max. Unit per Branch |
5 |
4 |
3 |
3 |
3 |
| Power Factor Adjustment Range |
0.9 leading-0.9 lagging |
| Total Current Harmonic Distortion THDi |
<3% |
| DC Injection Current |
<0.5%In |
| Efficiency |
| Max. Efficiency |
96.5% |
| Euro Efficiency |
96.0% |
| MPPT Efficiency |
>99% |
| Equipment Protection |
| DC Reverse Polarity Protection |
Yes |
| AC Output Overcurrent Protection |
Yes |
| AC Output Overvoltage Protection |
Yes |
| AC Output Short Circuit Protection |
Yes |
| Thermal Protection |
Yes |
| Insulation Impedance Detection |
Yes |
| Anti-islanding Protection |
Yes |
| Surge Protection Level |
TYPE III(AC) |
| General Data |
| Operating Temperature Range (°C) |
-40 to +65°C, >45°C Derating |
| Permissible Ambient Humidity |
0-100% |
| Permissible Altitude (m) |
2000m |
| Noise (dB) |
≤25 |
| Ingress Protection(IP) Rating |
IP 67 |
| Inverter Topology |
Isolated |
| Over Voltage Category |
OVC II(DC), OVC III(AC) |
| Communication |
Wi-Fi |
| Cabinet Size (W×H×D mm) (Excluding Connectors and Brackets) |
311×250.5×36.5 |
358×255.5×36.5 |
| Weight (kg) |
5.1 |
5.2 |
| Warranty |
10 Years |
| Type of Cooling |
Natural Cooling |
| Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105 |
| Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |