Hybrid AC/DC Solar Air Conditioner
Eco-friendly and powerful, the Hybrid AC/DC solar air conditioner can be powered by solar energy or traditional electricity, making it perfect for off-grid living or reducing your carbon footprint.
- 100% energy saving in the daytime. Only solar panel drive.
- AC grid power limiter, limits AC power from 0-600W
- AC power mode, DC power mode, AC+DC mix power supply (AC/DC Auto Balance)
- No inverter, no battery, no charge controller
- Full DC-driven
- Wide operating temperature (-10℃ to 58 ℃)
- Long warranty years
Description
The Hybrid AC/DC solar air conditioner from Deye delivers 100% solar-powered operation during the daytime without needing batteries or an inverter. Advanced controls automatically balance between solar DC power and supplemental AC electricity from the grid to maintain efficient water heating.
At the core of the system is its capability to extract sufficient heat using just the DC output of photovoltaic panels on sunny days. This enables substantial energy savings compared to conventional electric heaters. An integrated AC power limiter provides up to 600W of backup grid power if needed to ensure reliable water temperature.
Easy switching between solar DC mode, AC-only mode, or auto-balanced AC/DC dual power allows flexibility. Useful features like WiFi monitoring, app control, and multiple operating modes optimize hot water availability and comfort.
Built to withstand extreme ambient temperatures from -10°C to 58°C, the Hybrid AC/DC Solar Air Water Heater is ideal for tropical climates. It delivers high airflow volumes up to 3300 m3/h for effective heating performance. The unit does not need batteries, inverters or charge controllers, ensuring hassle-free operation.
With its renewable solar technology and generous warranty coverage, Deye’s Hybrid AC/DC solar air conditioner reduces electricity costs while sustaining a hot water supply.
Contact us for more details on sizing and installation recommendations.
Product Parameters
T3/T1 Hybrid AC/DC solar air conditioner | |||||
Model | Unit | DGA2-ACDCBLW-12K | DGA1-ACDCBLW-18K | DGA1-ACDCBLW-24K | |
Climate Type | Tropical</= 58℃ | T3/T1 | T3/T1 | T3/T1 | |
Application area | m2 | 12-20 | 20-30 | 30-42 | |
Power Supply | AC Power | Ph-V-Hz | 1Ph 208V-240V/50-60HZ | 1Ph 208V-240V/50-60HZ | 1Ph 208V-240V/50-60HZ |
DC Power (PV in Series) | V | 80-380V | 80-380V | 80-380V | |
DC Power Current | A | </=10A | </=10A | </=10A | |
Adviced Solar Panel | Pcs | (3-4)*330W in series | (3-6)*330W in series | (3-8)*330W in series | |
Rated Cooling | Capacity(T1) | W | 3510(900-3900) | 5070(1200-6000) | 6450(1800-7900) |
BTU | 12000(3000-13300) | 17300(4100-20400) | 22000(6100-27000) | ||
Power input(T1) | W | 940(190-1270) | 1400(220-2100) | 1790(300-3200) | |
Capacity(T3) | W | 2910 | 4290 | 5130 | |
BTU | 9900 | 14700 | 17500 | ||
Power input(T3) | W | 1050 | 1630 | 1940 | |
Rated Heating | Capacity | W | 4100(1000-4500) | 6100(1200-6800) | 7800(1800-9100) |
BTU | 14000(3000-15300) | 20800(4100-23000) | 26600(6100-31000) | ||
Power input | W | 1170(190-1700) | 1770(220-2500) | 2290(300-3500) | |
T1 EER (W/W)/ (BTU/W) | / | 3.75/12.75 | 3.60/12.35 | 3.60/12.30 | |
T3 EER (W/W)/ (BTU/W) | / | 2.75/9.45 | 2.65/9.00 | 2.65/9.00 | |
COP (W/W)/ (BTU/W) | / | 3.50/11.95 | 3.45/11.75 | 3.40/11.60 | |
Dehumidification capacity | L/h | 1.3 | 1.7 | 2.5 | |
Compressor | Model | / | WHP04200 | WHP05600 | 5RD198 |
Type | / | 2xRotary Inverter | 2xRotary Inverter | 2xRotary Inverter | |
Brand | / | Highly | Highly | Panasonic | |
Indoor fan motor | Model | BLDC-15W | BLDC-45W | BLDC-45W | |
Speed(Turbo/Hi/Mi/Lo) | r/min | 1300/1200/1100/950 | 1050/950/850/750 | 1350/1250/1150/1000 | |
Indoor air flow(Turbo/Hi/Mi/Lo) | m3/h | 540/485/435/350 | 980/880/740/620 | 1290/1180/1070/900 | |
Indoor noise level (Turbo) | dB(A) | ≤42.5 | ≤46 | ≤50 | |
Indoor unit | Dimension(W×H×D) | mm | 840×205×295 | 1080×330×237 | 1080×330×237 |
Packing (W×H×D) | mm | 920×290×360 | 1140×300×382 | 1140×300×382 | |
Net weight/Gross weight | Kg | 9.0/12.5 | 15.0/18.5 | 15.0/18.5 | |
Outdoor fan motor | Model | / | BLDC-40W | BLDC-55W | BLDC-75W |
Speed | r/min | 880 | 880 | 850 | |
Outdoor air flow | m3/h | 2100 | 2200 | 3300 | |
Outdoor noise level | dB(A) | ≤52 | ≤55 | ≤58 | |
Outdoor unit | Dimension(W×H×D) | mm | 802×564×323 | 802×564×323 | 900×700×337 |
Packing (W×H×D) | mm | 910×622×405 | 910×622×405 | 1006×755×418 | |
Net/Gross weight | Kg | 33.5/37.5 | 37/42.0 | 50/54.5 | |
Refrigerant type | / | R410A | R410A | R410A | |
Max Design pressure | MPa | 4.3/1.5 | 4.3/1.5 | 4.3/1.5 | |
Refrigerant copper pipe | Gas side/Liquid side (inch) | inch | 3/8 1/4 | 1/2 1/4 | 1/2 1/4 |
Max. refrigerant pipe length | m | 15 | 20 | 25 | |
Max. difference in level | m | 8 | 10 | 10 | |
Drain pipe size | mm | 16 | 16 | 16 | |
Refrigerant connction copper pipe length | m | 3 | 4 | 4 | |
Connection wire length | m | 4 | 5 | 5 | |
Electronic Expansion Valve | / | Yes | Yes | Yes | |
Loading QTY 40″ Hq/ 20″GP | Sets | 200/85 | 160/75 | 115/50 |