Description
SUN-3/3.6/5/6K-SG04LP1-EU Single Phase Hybrid Inverter |
|||||
|---|---|---|---|---|---|
| Model | SUN-3K-SG04LP1-24-EU | SUN-3K-SG04LP1-EU | SUN-3.6K-SG04LP1-EU | SUN-5K-SG04LP1-EU | SUN-6K-SG04LP1-EU |
|---|---|---|---|---|---|
| Battery Input Data | |||||
| Battery Type | Lead-acid or Lithium-ion | ||||
| Battery Voltage Range (V) | 20-30 | 40-60 | 40-60 | 40-60 | 40-60 |
| Max. Charging Current (A) | 140 | 70 | 90 | 120 | 135 |
| Max. Discharging Current (A) | 140 | 70 | 90 | 120 | 135 |
| Charging Strategy for Li-ion Battery | Self-adaptation to BMS | ||||
| Number of Battery Input | 1 | ||||
| PV String Input Data | |||||
| Max. PV Access Power (W) | 6000 | 6000 | 7200 | 10000 | 12000 |
| Max PV Input Power (W) | 4800 | 4800 | 5760 | 8000 | 9600 |
| Max PV Input Voltage (V) | 500 | ||||
| Start-up Voltage (V) | 125 | ||||
| MPPT Voltage Range (V) | 150-425 | ||||
| Rated PV Input Voltage (V) | 370 | ||||
| Max Operating PV Input Current (A) | 13 | 13+13 | |||
| Max Input Short-Circuit Current (A) | 17 | 17+17 | |||
| No.of MPP Trackers/No.of Strings MPP Tracker | 1/1 | 2/1+1 | |||
| AC Input/Output Data | |||||
| Rated AC Input/Output Active Power (W) | 3000 | 3600 | 5000 | 6000 | |
| Max AC Input/Output Apparent Power (VA) | 3300 | 3960 | 5500 | 6600 | |
| Rated AC Input/Output Current (A) | 13.6/13 | 16.4/15.7 | 22.7/21.7 | 27.3/26.1 | |
| Max AC Input/Output Current (A) | 15/14.3 | 18/17.2* | 25/23.9 | 30/28.7 | |
| Max Continuous AC Passthrough (grid to load) (A) | 35 | 40 | |||
| Peak Power off-grid (W) | 2 times of rated power,10s | ||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Rated Input/Output Voltage/Range (V) | 220/230, 0.85Un-1.1Un | ||||
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||
| Grid Connection Form | L+N+PE | ||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
| DC Injection Current | <0.5% In | ||||
| Equipment Protection | |||||
| Integrated |
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
||||
| Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||||